{"id":94,"date":"2015-04-24T07:34:16","date_gmt":"2015-04-24T07:34:16","guid":{"rendered":"http:\/\/www.safekom.pl\/blog\/?p=94"},"modified":"2015-04-24T07:34:16","modified_gmt":"2015-04-24T07:34:16","slug":"cisco-asr-gdy-swieci-crit","status":"publish","type":"post","link":"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/","title":{"rendered":"Cisco ASR &#8211; gdy \u015bwieci CRIT"},"content":{"rendered":"<p>Ostatnio zauwa\u017cy\u0142em \u017ce na ASR&#8217;ach \u015bwieci mi czerwona dioda CRIT &#8211; co robimy?<\/p>\n<p>1. sprawdzamy co si\u0119 dzieje na urz\u0105dzeniu<\/p>\n<pre>show facility-alarm status<\/pre>\n<p>wynik:<\/p>\n<pre>System Totals Critical: 1 Major: 0 Minor: 0\r\nSource Time Severity Description [Index]\r\n------ ------ -------- -------------------\r\nxcvr container 0\/0\/0 Feb 07 2015 21:45:35 INFO Transceiver Missing [0]\r\nxcvr container 0\/0\/1 Feb 07 2015 21:45:35 INFO Transceiver Missing [0]\r\nGigabitEthernet0\/0\/1 Apr 20 2015 01:26:59 CRITICAL Physical Port Link Down [1]\r\nGigabitEthernet0\/0\/3 Feb 07 2015 21:45:41 INFO Physical Port Administrative State Down [2]\r\nGigabitEthernet0\/0\/4 Feb 07 2015 21:45:41 INFO Physical Port Administrative State Down [2]\r\nGigabitEthernet0\/0\/5 Feb 07 2015 21:45:42 INFO Physical Port Administrative State Down [2]<\/pre>\n<p>2. Je\u017celi wszystko jest ok i nie wymaga serwisu czy\u015bcimy alarmy:<\/p>\n<pre>clear facility-alarm<\/pre>\n<p>mamy do wyboru typ alarmu jeszcze kt\u00f3ry mo\u017cemy skasowa\u0107:<\/p>\n<pre>#clear facility-alarm ?\r\n critical Clear critical (audible) facility alarms\r\n hw-module Hardware module alarms\r\n major Clear major (audible) facility alarms\r\n minor Clear minor (audible) facility alarms<\/pre>\n<p>w mym przypadku nie mog\u0142em skasowa\u0107 critical &#8211; musia\u0142em wy\u0142\u0105czy\u0107 administracyjnie \u00a0nie u\u017cywany interfejs\u00a0GigabitEthernet0\/0\/1 w kt\u00f3rym wymienia\u0142em wk\u0142adk\u0119 SFP.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Ostatnio zauwa\u017cy\u0142em \u017ce na ASR&#8217;ach \u015bwieci mi czerwona dioda CRIT &#8211; co robimy? 1. sprawdzamy co si\u0119 dzieje na urz\u0105dzeniu show facility-alarm status wynik: System Totals Critical: 1 Major: 0 Minor: 0 Source Time Severity Description [Index] &#8212;&#8212; &#8212;&#8212; &#8212;&#8212;&#8211; &#8212;&#8212;&#8212;&#8212;&#8212;&#8212;- xcvr container 0\/0\/0 Feb 07 2015 21:45:35 INFO Transceiver Missing [0] xcvr container 0\/0\/1 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"jetpack_post_was_ever_published":false,"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":false,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"enabled":false},"version":2}},"categories":[4],"tags":[37,13,18],"class_list":["post-94","post","type-post","status-publish","format-standard","hentry","category-cisco","tag-asr","tag-cisco","tag-router"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Cisco ASR - gdy \u015bwieci CRIT - SafeKom Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Cisco ASR - gdy \u015bwieci CRIT - SafeKom Blog\" \/>\n<meta property=\"og:description\" content=\"Ostatnio zauwa\u017cy\u0142em \u017ce na ASR&#8217;ach \u015bwieci mi czerwona dioda CRIT &#8211; co robimy? 1. sprawdzamy co si\u0119 dzieje na urz\u0105dzeniu show facility-alarm status wynik: System Totals Critical: 1 Major: 0 Minor: 0 Source Time Severity Description [Index] ------ ------ -------- ------------------- xcvr container 0\/0\/0 Feb 07 2015 21:45:35 INFO Transceiver Missing [0] xcvr container 0\/0\/1 [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/\" \/>\n<meta property=\"og:site_name\" content=\"SafeKom Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/safekompl\" \/>\n<meta property=\"article:published_time\" content=\"2015-04-24T07:34:16+00:00\" \/>\n<meta name=\"author\" content=\"Micha\u0142 Iwa\u0144czuk\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@MIwaczuk\" \/>\n<meta name=\"twitter:site\" content=\"@MIwaczuk\" \/>\n<meta name=\"twitter:label1\" content=\"Napisane przez\" \/>\n\t<meta name=\"twitter:data1\" content=\"Micha\u0142 Iwa\u0144czuk\" \/>\n\t<meta name=\"twitter:label2\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minuta\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/\"},\"author\":{\"name\":\"Micha\u0142 Iwa\u0144czuk\",\"@id\":\"https:\/\/www.safekom.pl\/blog\/#\/schema\/person\/fd4cc931b624af4b7353d36d92ba7181\"},\"headline\":\"Cisco ASR &#8211; gdy \u015bwieci CRIT\",\"datePublished\":\"2015-04-24T07:34:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/\"},\"wordCount\":83,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.safekom.pl\/blog\/#organization\"},\"keywords\":[\"asr\",\"cisco\",\"router\"],\"articleSection\":[\"Cisco\"],\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/\",\"url\":\"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/\",\"name\":\"Cisco ASR - gdy \u015bwieci CRIT - SafeKom Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.safekom.pl\/blog\/#website\"},\"datePublished\":\"2015-04-24T07:34:16+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Strona g\u0142\u00f3wna\",\"item\":\"https:\/\/www.safekom.pl\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Cisco ASR &#8211; gdy \u015bwieci CRIT\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.safekom.pl\/blog\/#website\",\"url\":\"https:\/\/www.safekom.pl\/blog\/\",\"name\":\"SafeKom Blog\",\"description\":\"Notatki Architekta i in\u017cyniera zwi\u0105zanego rozwi\u0105zaniami on-prem\",\"publisher\":{\"@id\":\"https:\/\/www.safekom.pl\/blog\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.safekom.pl\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.safekom.pl\/blog\/#organization\",\"name\":\"SafeKom Blog\",\"url\":\"https:\/\/www.safekom.pl\/blog\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\/\/www.safekom.pl\/blog\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/i0.wp.com\/www.safekom.pl\/blog\/wp-content\/uploads\/2015\/05\/cropped-logo.png?fit=512%2C512&ssl=1\",\"contentUrl\":\"https:\/\/i0.wp.com\/www.safekom.pl\/blog\/wp-content\/uploads\/2015\/05\/cropped-logo.png?fit=512%2C512&ssl=1\",\"width\":512,\"height\":512,\"caption\":\"SafeKom Blog\"},\"image\":{\"@id\":\"https:\/\/www.safekom.pl\/blog\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/safekompl\",\"https:\/\/x.com\/MIwaczuk\",\"https:\/\/www.linkedin.com\/in\/michaliwanczuk\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.safekom.pl\/blog\/#\/schema\/person\/fd4cc931b624af4b7353d36d92ba7181\",\"name\":\"Micha\u0142 Iwa\u0144czuk\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\/\/www.safekom.pl\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/cc6dda4ee8d21d1f254147e5ee6f5e38881b88a4a12a5774ca42380597e52014?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/cc6dda4ee8d21d1f254147e5ee6f5e38881b88a4a12a5774ca42380597e52014?s=96&d=mm&r=g\",\"caption\":\"Micha\u0142 Iwa\u0144czuk\"},\"description\":\"Pasjonat komputerowy od zawsze oraz maniak w zakresie sieci, wirtualizacji oraz bezpiecze\u0144stwa IT. Kompetentny in\u017cynier z du\u017cym do\u015bwiadczeniem w realizacji projekt\u00f3w informatycznych i telekomunikacyjnych. Wieloletni administrator IT, kt\u00f3ry utrzymuje systemy informatyczne dostosowuj\u0105c je do wymog\u00f3w biznesowych z zapewnieniem dost\u0119pno\u015bci 24\/7\/365.\",\"url\":\"https:\/\/www.safekom.pl\/blog\/author\/admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Cisco ASR - gdy \u015bwieci CRIT - SafeKom Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/","og_locale":"pl_PL","og_type":"article","og_title":"Cisco ASR - gdy \u015bwieci CRIT - SafeKom Blog","og_description":"Ostatnio zauwa\u017cy\u0142em \u017ce na ASR&#8217;ach \u015bwieci mi czerwona dioda CRIT &#8211; co robimy? 1. sprawdzamy co si\u0119 dzieje na urz\u0105dzeniu show facility-alarm status wynik: System Totals Critical: 1 Major: 0 Minor: 0 Source Time Severity Description [Index] ------ ------ -------- ------------------- xcvr container 0\/0\/0 Feb 07 2015 21:45:35 INFO Transceiver Missing [0] xcvr container 0\/0\/1 [&hellip;]","og_url":"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/","og_site_name":"SafeKom Blog","article_publisher":"https:\/\/www.facebook.com\/safekompl","article_published_time":"2015-04-24T07:34:16+00:00","author":"Micha\u0142 Iwa\u0144czuk","twitter_card":"summary_large_image","twitter_creator":"@MIwaczuk","twitter_site":"@MIwaczuk","twitter_misc":{"Napisane przez":"Micha\u0142 Iwa\u0144czuk","Szacowany czas czytania":"1 minuta"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/#article","isPartOf":{"@id":"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/"},"author":{"name":"Micha\u0142 Iwa\u0144czuk","@id":"https:\/\/www.safekom.pl\/blog\/#\/schema\/person\/fd4cc931b624af4b7353d36d92ba7181"},"headline":"Cisco ASR &#8211; gdy \u015bwieci CRIT","datePublished":"2015-04-24T07:34:16+00:00","mainEntityOfPage":{"@id":"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/"},"wordCount":83,"commentCount":0,"publisher":{"@id":"https:\/\/www.safekom.pl\/blog\/#organization"},"keywords":["asr","cisco","router"],"articleSection":["Cisco"],"inLanguage":"pl-PL","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/","url":"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/","name":"Cisco ASR - gdy \u015bwieci CRIT - SafeKom Blog","isPartOf":{"@id":"https:\/\/www.safekom.pl\/blog\/#website"},"datePublished":"2015-04-24T07:34:16+00:00","breadcrumb":{"@id":"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-asr-gdy-swieci-crit\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Strona g\u0142\u00f3wna","item":"https:\/\/www.safekom.pl\/blog\/"},{"@type":"ListItem","position":2,"name":"Cisco ASR &#8211; gdy \u015bwieci CRIT"}]},{"@type":"WebSite","@id":"https:\/\/www.safekom.pl\/blog\/#website","url":"https:\/\/www.safekom.pl\/blog\/","name":"SafeKom Blog","description":"Notatki Architekta i in\u017cyniera zwi\u0105zanego rozwi\u0105zaniami on-prem","publisher":{"@id":"https:\/\/www.safekom.pl\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.safekom.pl\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/www.safekom.pl\/blog\/#organization","name":"SafeKom Blog","url":"https:\/\/www.safekom.pl\/blog\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.safekom.pl\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/i0.wp.com\/www.safekom.pl\/blog\/wp-content\/uploads\/2015\/05\/cropped-logo.png?fit=512%2C512&ssl=1","contentUrl":"https:\/\/i0.wp.com\/www.safekom.pl\/blog\/wp-content\/uploads\/2015\/05\/cropped-logo.png?fit=512%2C512&ssl=1","width":512,"height":512,"caption":"SafeKom Blog"},"image":{"@id":"https:\/\/www.safekom.pl\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/safekompl","https:\/\/x.com\/MIwaczuk","https:\/\/www.linkedin.com\/in\/michaliwanczuk\/"]},{"@type":"Person","@id":"https:\/\/www.safekom.pl\/blog\/#\/schema\/person\/fd4cc931b624af4b7353d36d92ba7181","name":"Micha\u0142 Iwa\u0144czuk","image":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.safekom.pl\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/cc6dda4ee8d21d1f254147e5ee6f5e38881b88a4a12a5774ca42380597e52014?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/cc6dda4ee8d21d1f254147e5ee6f5e38881b88a4a12a5774ca42380597e52014?s=96&d=mm&r=g","caption":"Micha\u0142 Iwa\u0144czuk"},"description":"Pasjonat komputerowy od zawsze oraz maniak w zakresie sieci, wirtualizacji oraz bezpiecze\u0144stwa IT. Kompetentny in\u017cynier z du\u017cym do\u015bwiadczeniem w realizacji projekt\u00f3w informatycznych i telekomunikacyjnych. Wieloletni administrator IT, kt\u00f3ry utrzymuje systemy informatyczne dostosowuj\u0105c je do wymog\u00f3w biznesowych z zapewnieniem dost\u0119pno\u015bci 24\/7\/365.","url":"https:\/\/www.safekom.pl\/blog\/author\/admin\/"}]}},"jetpack_publicize_connections":[],"jetpack_featured_media_url":"","jetpack_shortlink":"https:\/\/wp.me\/p7i9ri-1w","jetpack-related-posts":[{"id":624,"url":"https:\/\/www.safekom.pl\/blog\/cisco\/asav-activestandby-konfiguracja-minimalna\/","url_meta":{"origin":94,"position":0},"title":"ASAv &#8211; Active\/Standby konfiguracja &#8211; minimalna","author":"Micha\u0142 Iwa\u0144czuk","date":"09.03.2016","format":false,"excerpt":"Witam, wcze\u015bniej napisa\u0142em jak w labie postawi\u0107 Cisco ASAv, dzi\u015b poka\u017c\u0119 jak szybko i bez problem\u00f3w skonfigurowa\u0107 dwie wirtualki w trybie failover A\/P - jedyny tryb kt\u00f3ry obs\u0142uguje na chwil\u0119 obecn\u0105. Rysunek pogl\u0105dowy: Za\u0142o\u017cenia konfiguracyjne: Interfejs Praimary Secondary zona GigabitEthernet 0\/0 192.168.1.80 192.168.1.81 NET_LAB GigabitEthernet 0\/1 172.16.1.1 172.16.1.2 LAN GigabitEthernet\u2026","rel":"","context":"In &quot;Cisco&quot;","block_context":{"text":"Cisco","link":"https:\/\/www.safekom.pl\/blog\/category\/cisco\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.safekom.pl\/blog\/wp-content\/uploads\/2015\/09\/cisco-logo.png?fit=400%2C300&ssl=1&resize=350%2C200","width":350,"height":200},"classes":[]},{"id":610,"url":"https:\/\/www.safekom.pl\/blog\/cisco\/asav-pierwsze-uruchomienie-w-labie\/","url_meta":{"origin":94,"position":1},"title":"ASAv &#8211; pierwsze uruchomienie w labie","author":"Micha\u0142 Iwa\u0144czuk","date":"06.03.2016","format":false,"excerpt":"Pierwsze uruchomienie Cisco ASAv w Labie. Pokazuj\u0119 podstawow\u0105 konfiguracj\u0119 od importu po zalogowanie si\u0119 po ssh lub asdm.","rel":"","context":"In &quot;Cisco&quot;","block_context":{"text":"Cisco","link":"https:\/\/www.safekom.pl\/blog\/category\/cisco\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.safekom.pl\/blog\/wp-content\/uploads\/2015\/09\/cisco-logo.png?fit=400%2C300&ssl=1&resize=350%2C200","width":350,"height":200},"classes":[]},{"id":123,"url":"https:\/\/www.safekom.pl\/blog\/cisco\/cisco-dwoch-operatorow-konfiguracja-routerow\/","url_meta":{"origin":94,"position":2},"title":"Cisco &#8211; dw\u00f3ch operator\u00f3w konfiguracja router\u00f3w","author":"Micha\u0142 Iwa\u0144czuk","date":"07.05.2015","format":false,"excerpt":"Dzi\u015b ci\u0119\u017cko dosta\u0107 adresacj\u0119 IPv4 aby uruchomi\u0107 BGP w biurze, aby mie\u0107 redundantne po\u0142\u0105czenie do Internetu. Tutaj skupi\u0119 na przypadku w kt\u00f3rym mamy dost\u0119p do Internetu przez dw\u00f3ch niezale\u017cnych dostawc\u00f3w Internetu ISP1 i ISP2. Konfiguracja poni\u017cej pozwala na dost\u0119p z adresacji prywatnej do Internetu, wszystko jest natowane na adresy publiczne\u2026","rel":"","context":"In &quot;Cisco&quot;","block_context":{"text":"Cisco","link":"https:\/\/www.safekom.pl\/blog\/category\/cisco\/"},"img":{"alt_text":"2_isp","src":"https:\/\/i0.wp.com\/www.safekom.pl\/blog\/wp-content\/uploads\/2015\/05\/2_isp-300x228.jpg?resize=350%2C200","width":350,"height":200},"classes":[]},{"id":693,"url":"https:\/\/www.safekom.pl\/blog\/cisco\/lab-vxvlan-pierwsze-podjescie\/","url_meta":{"origin":94,"position":3},"title":"LAB &#8211; VXVLAN pierwsze podje\u015bcie","author":"Micha\u0142 Iwa\u0144czuk","date":"03.04.2016","format":false,"excerpt":"Ostatnio uczestniczy\u0142em w ciekawym webbinarium zorganizowane przy forum CCIE.pl pod tytu\u0142em\u00a0DCI \"po nowemu\" - prezentacj\u0119 prowadzi\u0142\u00a0Piotr Jab\u0142o\u0144ski. Piotr pokazywa\u0142 jak w dzisiejszych czasach mo\u017cna wykorzysta\u0107 technologi\u0119 VXVLAN do rozci\u0105gania L2 pomi\u0119dzy DataCenter lub w samym DC. Po obejrzeniu stwierdzi\u0142em \u017ce trzeba zbudowa\u0107 laba i zobaczy\u0107 z czym si\u0119 to je\u2026","rel":"","context":"In &quot;Cisco&quot;","block_context":{"text":"Cisco","link":"https:\/\/www.safekom.pl\/blog\/category\/cisco\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.safekom.pl\/blog\/wp-content\/uploads\/2015\/09\/cisco-logo.png?fit=400%2C300&ssl=1&resize=350%2C200","width":350,"height":200},"classes":[]},{"id":782,"url":"https:\/\/www.safekom.pl\/blog\/cisco\/lab-vxlan-juniper-vmx-i-cisco-csr1kv-asav\/","url_meta":{"origin":94,"position":4},"title":"LAB vxlan &#8211; Juniper vMX i Cisco CSR1kv oraz ASAv","author":"Micha\u0142 Iwa\u0144czuk","date":"26.04.2016","format":false,"excerpt":"Po pierwszym wpisie o VxLAN, gdzie opar\u0142em si\u0119 wy\u0142\u0105cznie na Cisco CSRv oraz ASAv przysz\u0142a pora na testowanie w konfiguracji multivendor. Do tego laba wykorzysta\u0142em: Cisco CSRv Cisco ASAv Juniper vMX Wszystko zosta\u0142o uruchomione na Vmware Workstation. W dobie wirtualizacji serwer\u00f3w i desktop\u00f3w postanowi\u0142em wzi\u0105\u0107 si\u0119 ostro za poznanie \u015bwiata\u2026","rel":"","context":"In &quot;Cisco&quot;","block_context":{"text":"Cisco","link":"https:\/\/www.safekom.pl\/blog\/category\/cisco\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.safekom.pl\/blog\/wp-content\/uploads\/2016\/02\/Juniper-Networks-and-Cisco-Systems.png?fit=712%2C534&ssl=1&resize=350%2C200","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/www.safekom.pl\/blog\/wp-content\/uploads\/2016\/02\/Juniper-Networks-and-Cisco-Systems.png?fit=712%2C534&ssl=1&resize=350%2C200 1x, https:\/\/i0.wp.com\/www.safekom.pl\/blog\/wp-content\/uploads\/2016\/02\/Juniper-Networks-and-Cisco-Systems.png?fit=712%2C534&ssl=1&resize=525%2C300 1.5x, https:\/\/i0.wp.com\/www.safekom.pl\/blog\/wp-content\/uploads\/2016\/02\/Juniper-Networks-and-Cisco-Systems.png?fit=712%2C534&ssl=1&resize=700%2C400 2x"},"classes":[]},{"id":1220,"url":"https:\/\/www.safekom.pl\/blog\/huawei\/nowe-urzadzenie-na-warsztacie-czyli-pierwsze-starcie-z-huawei-usg\/","url_meta":{"origin":94,"position":5},"title":"nowe urz\u0105dzenie na warsztacie &#8211; czyli pierwsze starcie z Huawei USG","author":"Micha\u0142 Iwa\u0144czuk","date":"14.10.2016","format":false,"excerpt":"Po d\u0142ugim poszukiwaniu dost\u0119pu do urz\u0105dzenia Huawei z rodziny firewall, dzi\u0119ki uprzejmo\u015bci firmy S4E, uda\u0142o mi si\u0119 dosta\u0107 w r\u0119ce model\u00a0USG6330. Zobaczymy co przys\u0142owiowy \"chi\u0144czyk\" potrafi i jak bardzo r\u00f3\u017cni si\u0119 on od mo\u017cliwo\u015bci urz\u0105dze\u0144 typu PaloAlto czy Fortinet. Nie b\u0119d\u0119 tutaj si\u0119 skupia\u0107 na aspektach wydajno\u015bciowych - nie b\u0119d\u0119\u2026","rel":"","context":"In &quot;Huawei&quot;","block_context":{"text":"Huawei","link":"https:\/\/www.safekom.pl\/blog\/category\/huawei\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/www.safekom.pl\/blog\/wp-content\/uploads\/2016\/10\/Huawei-Logo-e1394619656563.png?fit=400%2C389&ssl=1&resize=350%2C200","width":350,"height":200},"classes":[]}],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.safekom.pl\/blog\/wp-json\/wp\/v2\/posts\/94","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.safekom.pl\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.safekom.pl\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.safekom.pl\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.safekom.pl\/blog\/wp-json\/wp\/v2\/comments?post=94"}],"version-history":[{"count":0,"href":"https:\/\/www.safekom.pl\/blog\/wp-json\/wp\/v2\/posts\/94\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.safekom.pl\/blog\/wp-json\/wp\/v2\/media?parent=94"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.safekom.pl\/blog\/wp-json\/wp\/v2\/categories?post=94"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.safekom.pl\/blog\/wp-json\/wp\/v2\/tags?post=94"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}